First: start the pump when the micro-motor does not rotate.

the reason:

1. Supporting switch DC power supply failure;

2 battery or battery is not enough power;

3. bad line contact;

4. motor and carbon brush bad;

Second: start the pump motor but no water.

the reason:

1. There are debris or impurities in the pump;

2. Suction pump suction stroke above the rated;

Third: lack of traffic.

the reason:

1. The actual pump head lift more than allowed;

2. The voltage is too low, the motor speed is slow;

Suction too high

Water pipe

Fourth: the traffic becomes smaller. the reason:

1. The inlet is blocked by impurities

2. Filter used for too long, there are particles of impurities blocked;

Fifth: micro water pump abnormal interruption of water.

the reason:

1. The motor is not started, to eliminate circuit failure;

2. pipeline blocked, remove clogs;

Pipe rupture, repair welding or for praise;

4 filter plugging, remove clogs;

5. Suction outlet pipe exposed surface;

Sixth: pump running violent vibration or abnormal increase.

the reason:

1. Access voltage is higher than the set voltage;

2. Installation angle is not fixed;

3. Bending motor or pump shaft.