Box Forming Filling Packaging Machine For Beverage Water Packaging Machine,Filling Packaging Machine,Beverage Water Packaging Machine ST Machinery Co.,Ltd , https://www.yzstmachinery.com
Application
1. Food processing industry, including juices, milk, drinks, beer, practical oil and canned food.
2. Electronic industry.
3. Hospitals, various laboratory and high levels of pathogenic body water disinfection.
4. Households building, residential, office buildings, hotels, restaurants, water factories.
5. Purification and disinfection of shellfish, fish cleaning and disinfection process
6. Military camp, field water supply system
7. Urban wastewater disinfection.
8. Swimming pool, other recreational water disinfection
9. Thermal power, nuclear power plant industrial, central air conditioning system cooling water.
10. Biological, chemical and pharmaceutical, cosmetics for the production of cooling water.
11. Sea water, fresh water breeding, aquaculture water
Product application
Ultraviolet light treatment is a widely recognized and proven method of disinfection of water and has several advantage over other disinfection methods such as chlorination, ozonation, etc. Uv light does not add anything to the water, such as, undesirable color, odor, taste, or flavor, nor does it generate harmful byproducts. It adds only energy in the uv radiation. Also, uv disinfection requires only a fraction of the contact times required by other disinfection methods. It is fast, efficient, effective, economical and environmentally-friendly.
Principle of operation
Uv water disinfection system design has been carefully conceived to provide adequate germicidal dosage
Throughout the disinfection chamber. The dosage, as it applies to uv disinfection, is a function of time and the intensity of uv radiation to which the water is exposed. Exposure time is related to the flow rate, the higher the flow rate, the lower the exposure time or the lower the flow rate, the higher the exposure time. The uv intensity is the amount of energy, per unit time, emitted by germicidal lamp. The dosage is the product of uv intensity and the exposure time.
Limitation of use
The uv water disinfection system not intended for the treatment of water that has an obvious contamination or intentional source, such as raw sewage, nor is the unit intended to convert wastewater to microbiologically safe drinking water.
Water quality (in)
Water quality plays a major role in the transmission of germicidal uv rays. It is recommended that the water does not exceed following maximum concentration levels
Maximum concentration levels (very important)
Iron: ≤ 0.3ppm(0.3mg/l)
Hardness: ≤ 7gpg(120mg/l)
Turbidity: ≤ 1ntu
Manganese: ≤ 0.05ppm(0.05mg/l)
Tannins: ≤ 0.1ppm(0.3mg/l)
Uv transmittance: ≥ 750‰
Effectively treating water with higher concentration levels than listed above can be accomplished, but may require added measures to improve water quality to treatable levels. If, for any reason, it is believed the uv transmission is not satisfactory, contact the factory.
Model No
Flow Rate(m 3 /h)
Â
All Lamps Power (W)
Â
In / Outlet inch
Â
Chamber dimensions (mm)
Â
mm
inches
PDCn-050
Â
2
Â
40
Â
25
Â
1"
Â
1000× Φ 89
Â
PDCn-150
Â
6
Â
80
Â
32
Â
1-1/4
Â
1000× 300× Φ 108
Â
PDCn-200
Â
8
Â
120
Â
40
Â
1-1/2
Â
1000× 400× Φ 159
Â
PDCn-300
Â
12
Â
160
Â
50
Â
2"
Â
1000× 400× Φ 159
Â
PDC-360
Â
15
Â
200
Â
65
Â
2-1/2"
Â
1000× 400× Φ 159
Â
PDC-500
Â
20
Â
240
Â
65
Â
2-1/2"
Â
1000× 500× Φ 219
Â
PDC-600
Â
25
Â
280
Â
80
Â
3"
Â
1000× 500× Φ 219
Â
PDC-700
Â
30
Â
320
Â
100
Â
4"
Â
1000× 500× Φ 219
Â
PDC-1000
Â
40
Â
360
Â
100
Â
4"
Â
1000× 500× Φ 219
Â
PDC-1300
Â
50
Â
435
Â
125
Â
5"
Â
1000× 570× Φ 273
Â
PDC-1500
Â
60
Â
620
Â
150
Â
6"
Â
1700× 570× Φ 273
Â
PDC-2000
Â
80
Â
775
Â
150
Â
6"
Â
1700× 570× Φ 273
Â
PDC-2500
Â
100
Â
930
Â
150
Â
6"
Â
1700× 570× Φ 273
Â
PDC-3000
Â
125
Â
1085
Â
150
Â
6"
Â
1700× 570× Φ 273
Â
PDC-4000
Â
150
Â
1240
Â
200
Â
8"
Â
1700× 570× Φ 325
Â
PDC-5000
Â
200
Â
1550
Â
200
Â
8"
Â
1700× 570× Φ 377
Â
PDC-7000
Â
300
Â
2170
Â
250
Â
10"
Â
1700× 570× Φ 426
Â
PDC-10K
Â
400
Â
2480
Â
Â
Â
Â
Â
Â
Â
PDC-15K
Â
600
Â
3100
Â
Â
Â
Â
Â
Â
Â
Note
 PDCn-050 to PDC-100 using 40w UV lamp
PDC-1300 using 87w UV lamp
PDC-1500 to PDC-12k using 155w UV lamp
PDCn is threaded connection, PDC is flange connection
Â
Drain inch
 1/2" threaded
Â
Lamp useful life
 Standard 9000 Hours
Â
UV lamp brand
 " Lightsource" from USA
Â
Single UV lamp
 40w in general. We can aslo supply 75w, 87w, 155w, 240w, 320w
Â
UV lamp select
 If you need we can aslo supply UV lamp which can generater ozone
Â
Chamber pressure
 Rated to 0.6Mpa. If you need higher pressure, please tell me
Â
Water temperature
 The appropriate temperature is 4 - 50 DEGREE (-5-60 degree range)
Â
Packing
 Wooden packaging
Â
Optional
 UV intensity monitor system
 Water temperature monitor system
 Time accumulator system
 Cleaning system: Maunal cleaning, Pneumatic cleaning and Electric cleaing
Â
Welcome to inquire, we will offer you the best items!
Model NO.: PDC
UV Wavelength: 253.7nm
UV Lamp: Lightsources
Power Supply: 40-4760W
Electricity: 220V 50Hz ,110V 60Hz
Cleaning Way: Manual or Electric Self-Clean
UV Intensity Monitor: Optional
Flow Rate: 1-1000 T/H
Trademark: PEIDE
Specification: ISO9001: 2008
Origin: China
HS Code: 8419200000
High Quality Drink Safety Water Sterilization Equipment