GB/T 6434-2006 Determination of crude fat in feed
1 Theme content and scope of application
This standard specifies the method for the determination of crude fat in feed. (The practical national standard method for measuring crude fat is time-consuming and inefficient. Therefore, if it is not necessary, we usually use an instrument for direct measurement, such as a crude fat analyzer. It has a variety of models, such as the SZF-06A crude fat analyzer, SZF- 06B crude fat analyzer, SZF-06 crude fat analyzer three, if friends need more information, you can call the 24-hour service hotline at any time
This standard applies to all kinds of single, mixed, compound feeds and premixes.
2 Principle
A Soxhlet fat extractor extracts the sample with ether and weighs the extract. Besides fat, it also contains organic acids, phospholipids, fat-soluble vitamins, chlorophyll, etc. The result is called crude fat or ether extract.
3 Reagents
3.1 Anhydrous ethyl ether (analytically pure).
4 Equipment
4.1 Sample grinders or mortars for laboratories.
4.2 Sample Screen: Aperture: 0.45mm.
4.3 Analytical balance: Sensitivity 0.0001g.
4.4 electric constant temperature water bath: room temperature ~ 100 °C.
4.5 constant temperature oven: 50 ~ 200 °C.
4.6 Soxhlet fat extractor (with spherical condenser): 100 or 150 mL.
4.7 Soxhlet fat extractor.
4.8 filter paper or filter paper tube: medium speed, degreasing.
4.9 Dryer: Use desalinizer with calcium chloride (dry grade) or discolored silica gel.
5 sample selection
A representative sample was selected and the sample was reduced to 500 g by quartering, comminuted to 40 mesh, and further reduced to 200 g in a sealed container using four minutes.
6 analysis steps
6.1 Arbitration method: Determined using a Soxhlet fat extractor.
The Soxhlet extractor (4.6) should be dry and dry. The extraction flask (with several zeolites inside) was dried in a 105±2°C oven (4.5) for 60 min, cooled in a desiccator (4.9) for 30 min, and weighed. After drying for 30 minutes, the same cooling and weighing, the difference between the two weights is less than 0.0008g is a constant weight.
Weigh the sample 1 ~ 5g (accurate to 0.0002g), in the filter paper tube, or wrapped with filter paper, placed in a 105 °C oven (4.5), drying 120min (or into the dry sample after the determination of water, converted into Air-dried sample weight), filter paper tube or bag into the extraction tube, add anhydrous ether (3.1) 60-100 mL in the extraction bottle, heating in a 60-75°C water bath (with distilled water), make ether (3.1) For reflux, control the reflux of ether (3.1) to about 10 times per hour, return 50 times in total (about 70 samples with high oil content) or check the ether (3.1) flowing out of the extraction tube and leave no trace of oil after pumping. To mention the end.
Take out the sample, there is still the original extractor to recover ether until the extraction bottle is completely finished, remove the extraction bottle, and evaporate the residual ether on the water bath. Wipe the outer wall of the bottle. Put the extraction bottle into a 105±2°C oven (4.5) to dry it for 120 min, cool it in a desiccator (4.9) for 30 min, and then dry it for 30 min, and then cool and weigh. The difference between the two weights is less than 0.001g. weight.
6.2 Recommended Method: Determined using a fat extractor (4.7). According to each instrument operating instructions for the determination.
7 Calculation of measurement results
7.1 Calculation See the following formula
Crude fat (%)=(m2-m1)×100/m
Where: m - air-dried sample weight, g.
M1-- The weight of the extracted bottle, g.
M2-- The weight of the extracted bottle with constant weight, g.
7.2 Repeatability
Each sample was taken twice in parallel and the arithmetic average was used as the result.
When the crude fat content is ≥10%, the allowable relative deviation is 3%.
When the crude fat content is 10%, the relative deviation is 5%.

Powder Benzoin For Powder Coating

Application:


As a degass agent should be add to premix with 0.3~0.5% of total frmulation for degassing bubbles during extrusion to eliminate or reduce those imperfections like pinholes. It can be applied in all kind of powder coatings.

The acurate amount should be obtained in lab. The dosage should be properly controlled to get suitable film, as superfluous Benzoin may cause

yellowing phenomena.


Our Advantage & Service:
-Technical Support Online Service Provided


According to customer's requirement, we provide layout (plant designer), excellent mechanical engineer, excellent electrician, etc.


-On-site Training Service Provided


In customer factory, we provide all kinds of training, including installation, commissioning


-Long-term Maintenance Provided


In the area of maintenance, we offer needs-oriented and standardized maintenance packages, such as the overhaul of components, gearboxes, in order to guarantee the safe and economic operation of plant and machinery.


-Spare Parts Replacement and Repair Service Provided


Providing spare parts for all kinds of powder coating processing equipment in long-term. And can provide tailored made spare parts according to customers' requirements. Ensure advanced craft, good material and high precision.


-Formulation Provided (our advantage)


Some customers are worried their final products if can get best result, we have our own formulator (Engineer for powder coating formulation) who is testing and updating the formulation according to customer requirement all the time. And have very good experience for the formulation to support customer to make different effect powder coatings.

Powder Coating Benzoin,Degassing Agent Benzoin,Powder Coating Anti-Yellowing Benzoin,Powder Coating Diphenylethanone

Yantai Yuanli Corp Ltd , https://www.yuanlicorpcn.com